An addendum to the AAPMˈs TG-51 protocol for the determination of absorbed dose to water in megavoltage photon beams is presented. This addendum continues the procedure laid out in TG-51 but newkQ data for photon beams, based on Monte Carlo simulations, are presented and recommendations are given to improve the accuracy and consistency of the protocolˈs implementation. The components of the uncertainty budget in determining absorbed dose to water at the reference point are introduced and the magnitude of each component discussed. Finally, the consistency of experimental determination ofND,w coefficients is discussed. It is expected that the implementation of this addendum will be straightforward, assuming that the user is already familiar with TG-51. The changes introduced by this report are generally minor, although new recommendations could result in procedural changes for individual users. It is expected that the effort on the medical physicistˈs part to implement this addendum will not be significant and could be done as part of the annual linac calibration.
This report is an addendum to Report 067
Issue Details
March 11, 2014
Published Date
Issue Number
Volume Number
2014
Document Year
067.A1
Document Number
ISBN